Skip to content
English
Menu

Spaces

  • Remote Lab
  • KNX Tools — Not available from here yet

Remote Lab

Account

SBE Academy

KNX HVAC Specialist Online

Preview of the upcoming course: understand, program and troubleshoot a real KNX HVAC installation remotely.

Course content: FR · EN

Loading your progress…

Modules7

  1. HVAC-INTRO-01

    Understanding the HVAC chain

    Understand who requests, produces and distributes heat, from the room to the boiler room.

    Not started1 h
    1. Understand — to do
    2. Simulate — to do
    3. Program — not part of this module
    4. Analyse — not part of this module
    5. Validate — to do
  2. HVAC-TERM-01

    ON/OFF terminal unit control

    Connect a real thermostat and a real switching actuator to a virtual room and observe the valve command.

    Not started1 h 30 min
    1. Understand — to do
    2. Simulate — not part of this module
    3. Program — to do
    4. Analyse — to do
    5. Validate — to do
  3. HVAC-FC-01

    2-pipe fan coil

    A real thermostat and a real Theben FCA 2 fan coil actuator drive the simulated fan coil of a virtual room: speeds, 2-pipe heating and cooling.

    Not started1 h 40 min
    1. Understand — to do
    2. Simulate — not part of this module
    3. Program — to do
    4. Analyse — to do
    5. Validate — to do
  4. HVAC-FC-02

    4-pipe fan coil

    Extension — 4-pipe fan coil and heating / cooling stability: two commands, a dead band, and an accelerated day to see their effects.

    Not started1 h
    1. Understand — to do
    2. Simulate — not part of this module
    3. Program — to do
    4. Analyse — to do
    5. Validate — to do
  5. HVAC-ROOM-01

    HVAC modes, setpoints and window information

    Window, HVAC modes and setpoints: the real Zennio thermostat from HVAC-FC-02 receives the building context, and the simulated room reacts to the window.

    Not started1 h 15 min
    1. Understand — to do
    2. Simulate — to do
    3. Program — to do
    4. Analyse — to do
    5. Validate — to do
  6. HVAC-ROOM-02

    Multi-room temperature control

    Several rooms with different needs on a single boiler room: the building view (preview).

    Not started1 h 15 min
    1. Understand — to do
    2. Simulate — to do
    3. Program — not part of this module
    4. Analyse — to do
    5. Validate — not part of this module
  7. HVAC-PLANT-01

    AC/S and boiler room

    Understand and diagnose a simulated boiler room driven by a real AC/S.

    Not started2 h
    1. Understand — to do
    2. Simulate — not part of this module
    3. Program — not part of this module
    4. Analyse — to do
    5. Validate — to do

Progress is kept for this browser only, without an account.